Test: Uni-T UT612 LCR-Meter

posted in: electronics | 0
manufacturer: Uni-T
modell: UT612 LCR-Meter (2015 modell)
calibration: before measurement (open circuit and shotcut)
measurement: with supplied measuring bridge
testobject: 2x foil capacitor (manufacturer: Yageo, C = 220 µF, Umax = 250 V, SEK 105°C, 08/2008)

 

Results for capacitor 1:

f in Hz C in µF D Q ESR in Ohm
100 186,81 0,033 29,9 0,20
120 186,46 0,036 27,0 0,20
1k 183,16 0,192 5,17 0,16
10k 174,60 1,678 0,595 0,15
100k n.a. n.a. n.a. n.a.

 

Results for capacitor 2:

f in Hz C in µF D Q ESR in Ohm
100 187,29 0,033 29,9 0,20
120 187,02 0,036 26,9 0,20
1k 183,92 0,192 5,18 0,16
10k 176,10 1,681 0,594 0,15
100k n.a. n.a. n.a. n.a.